Journal: Journal of Materials Engineering and Performance

Publication date: 15 September 2012

Abstract:

Inspection and quality control of induction hardened parts require a good understanding of the depth of the hardened layer. Traditional destructive methods to determine the case depth are considered to be costly and time-consuming. The eddy current (EC) technique is sensitive to micro-structural changes; hence, it can be used to determine the case depth based on the differences in magnetic properties between the hardened layer and the core of the specimen. In this study, identical rods of AISI 1045 mild carbon steel were surface hardened using induction hardening technique. In order to investigate the applicability of the EC technique, the relations between obtained effective and total case depths and the EC outputs (induced voltage, normalized impedance, phase angle, and their harmonic characteristics) were studied. The results show a maximum of correlation coefficient of 94% in determining case depths by EC technique.